Server Room Dedicated In Row Air Conditioning Unit Precise

Hefei Coolnet power Co., ltd
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now

Server Room Dedicated In Row Air Conditioning Unit Precise

Brand Name : COOLNET

Model Number : CYA,M08,CR012

Certification : CE,ISO

Place of Origin : CHINA

MOQ : 1set

Price : 1800-30000USD

Payment Terms : T/T, L/C

Supply Ability : 300 PCS PER MONTG

Delivery Time : 10-25 working days

Packaging Details : Packed in plywooden case, standard export package

Cooling capacity : 12kw-40kw

Condition : New

Mounting : Floor Standing Units

Type : In-Row AC Unit

Operating voltage : 380/400 VAC,230 VAC,220V

Warranty : 1 Year(12 month with no artificial damage)

Product name : Precision Air Conditioning Units

Refrigerant : R22(R407C/R410A)

Application : Data Center, IT room , Computer room, For Cold/hot aisle

Color : Black/Grey/White/Other custom colors

Fan type : EC fans

Power : 3N-380V-50Hz,220v/50hz/60hz

Airflow : 2000~20000 m3/h

Voltage : 380v/220v,220V/380V,380V/415V

Contact Now

Server Room Large Exchange Rooms Dedicated In-Row Precise Air Cooling Systems

Product Introduction

Coolnet DX series in-row air conditioners are air conditioners developed for the cooling of server racks in small, medium and large communication data centers. It is especially suitable for micro-module systems with closed hot and cold aisles. The Coolnet DX series features a row-oriented cooling architecture, with each CRAC unit dedicated to cooling a row of server racks. CRAC units can be installed between racks, overhead, or under the floor. Airflow paths are shorter and more clearly defined than room-based cooling. This reduces the required CRAC fan power, increasing efficiency. The row-oriented design also allows cooling capacity and redundancy to be tailored to the actual needs of a particular row, maximizing smooth server operation.

Feature and Benefits

Server Room Dedicated In Row Air Conditioning Unit Precise

Server Room Dedicated In Row Air Conditioning Unit Precise

Application

  • Large, medium and small exchange room and data center
  • Paging machine room and communication machine room
  • Microwave and satellite ground station
  • Field base stations and mobile telecommunications
  • Network management center and small computer room
  • UPS power room and battery room
  • CT and MRI room
  • Biochemical Incubation Room
  • Standardize testing rooms and calibration centers
  • Precision workshop and dust-free workshop
Server Room Dedicated In Row Air Conditioning Unit Precise

Structure & Componenets

Server Room Dedicated In Row Air Conditioning Unit Precise

EVO intelligent control system

Control the air volume and cooling output as required, and cooperate with EC fan, electronic expansion valve and DC inverter compressor to achieve the best effect and lowest energy consumption; Adjust the speed of the internal fan according to the refrigeration demand, which can effectively reduce the noise; Group control function, realize up to 32 sets of group operation, including automatic main-standby switching, automatic operation of backup units, round robin, competition avoidance operation, temperature and humidity sensor sharing, etc.;

DC Inverter Compressor of DX System

Dynamic cooling to adapt to the rapidly changing load of the computer room; Save energy and improve energy efficiency under low load; It can greatly reduce the number of compressor starts and stops, and improve system reliability

Backward Centrifugal EC Fan

Compared with ordinary standard AC motors, the electronically commutated synchronous EC motors can save energy by 30%;

Automatically adjust the fan speed according to the cooling demand or wind pressure, and provide the air volume on demand;

Fan N+1 redundant configuration, any fan failure can still ensure full air volume operation;

Soft start function, low starting current; Easy maintenance design

Server Room Dedicated In Row Air Conditioning Unit Precise

Technical Parameter

Model CRA013A CRA020A CRA040A CRA050A CRA060A
Air supply Front/Side Front/Side Front Front Front
Power supply 380VAC/3Ph/50Hz
Cooling capacity-KW 13.2 26.7 42.6 53.3 63.9
Sensible cooling-KW 13.2 26.7 42.6 53.3 63.9
Compressor
Refrigerant R410A
Quantity 1
Fan
Fan type EC Centrifugal fan
Quantity 4 5 2 3 3
Air volume-m3/h 3200 5000 8800 11000 12500
Heater
Heat type PTC
Capacity-KW 2 3 6 6 6
Humidification
Capacity-KW 1 1.5 3 3 3

Certificates

Server Room Dedicated In Row Air Conditioning Unit Precise

Factory Details

Server Room Dedicated In Row Air Conditioning Unit Precise

Packing & Delivery

Server Room Dedicated In Row Air Conditioning Unit Precise

Cases

Server Room Dedicated In Row Air Conditioning Unit Precise


Product Tags:

Dedicated In Row Air Conditioning Unit

      

In Row Air Conditioning Unit Precise

      

Precise In Row Cooling Unit

      
China Server Room Dedicated In Row Air Conditioning Unit Precise wholesale

Server Room Dedicated In Row Air Conditioning Unit Precise Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Hefei Coolnet power Co., ltd
*Subject:
*Message:
Characters Remaining: (0/3000)